Central Lubrication
Starting from 06/2023, the CMS machines are equipped with a central lubrication as a standard equipment.
(not for: CMS 703, CMS 503, CMS 502, CMS 303, CMS 202).
The central lubrication lubricates with oil the working butts of all needle bed elements:
- Holding-down jack
- Coupling part
- Intermediate slider (2 working butts)
- Selection jack (2 working butts)
The oil pump can be found either on the left or on the right machine side depending on the machine type.
Notes:
- Adjust the central lubrication.
Path: Configure Machine -> Maintenance -> Lubricating
-> Central Lubrication - Refill oil.
If the content level is undershot then the Central lubrication oil reservoir almost empty message appears.
Refill oil until the "Max" mark has been reached. - Grease the coupling parts and the intermediate sliders.
We recommend to grease the butts of the coupling parts and intermediate sliders even if the machine is equipped with central lubrication. - Refer to the manual of the central lubrication unit.
-> Enclosure on the control unit of the machine