Pseudo events for primary database

SKR2_TYPE_ POLLCLIENT (Event Type = 121)

Pseudo events for primary database

Event ID

ID Enum

Description

Change in status table

1

SKR2_POLLC_RESTORE_DATA

is inserted after a restore and after Read Archive.

Not for SKR3.

The status "unknown" (-1) is entered in all the xx_STATE tables.

2

SKR2_POLLC_REPAIR_TABLE

Not for SKR3.

 

3

SKR2_POLLC_MACHINE_REGTIME_STARTUP_PARAMETER

EVENT_PARAM field contains SW version states for internal purposes at the time of the registration of the machine in the SKR. For example : 1 /c=010 /v=1.V.1.2.5

 

4

SKR2_POLLC_DATA_GAP_OCCURED

A data gap occurred, due to the machine being operated too much time without network connection for example

 

Meaning of the fields of SKR2_POLLC_MACHINE_REGTIME_STARTUP_PARAMETER:
1 /c=010 /v=1.E.3.149.6

eSTARTUP_MODE /c=MCSpec /v=McControlGeneration.McOS-Version

(Identical toMC status events, Event Type = 2, Event ID = 32001)

eSTARTUP_MODE

Start mode

ecUndefined

0 - Undefined

ecWarmStart

1 - Warm start

ecDirectReStart

2 - Restart

ecReStart

3 – Restart with configuration

ecDirectColdStart

4 - Cold start
(when installing)

ecColdStart

5 - Cold start with configuration
(when installing with configuration)

ecReconfiguration

6 - Reconfiguration

(automatically done, e.g. with expiration of EVP, with mounting or removing Stixx or Ascon, with changing the coupling width of tandem machines)

MCSpec

Position of the digit

Digit 1

Tandem machine 0/1

Digit 2

Cancel Pattern Event possible (always 1)

Digit 3

Yarn consumption info available (0/1)

Further digits can occur in case of a function upgrade

McControlGeneration

Control generation

1

OKC

2

EKC

3

CKC

McOS Version

Version of operating system

Example

V.1.2.5 Corresponds to V_EKC_001.002.005_STOLL
E.3.149.6
Corresponds to E_OKC_003.149.006_STOLL