Pseudo events for primary database
SKR2_TYPE_POLLCLIENT (Event Type = 121)
Event ID |
ID Enum |
Description |
Change in status table |
---|---|---|---|
1 |
SKR2_POLLC_RESTORE_DATA |
is inserted after a restore and after Read Archive. Not for SKR3. |
The status "unknown" (-1) is entered in all the xx_STATE tables. |
2 |
SKR2_POLLC_REPAIR_TABLE |
Not for SKR3. |
|
3 |
SKR2_POLLC_MACHINE_REGTIME_STARTUP_PARAMETER |
The EVENT_PARAM column of the Event List Report contains SW version states for internal purposes at the time of the registration of the machine in the SKR. For example: 1 /c=010 /v=1.V.1.2.5 |
|
4 |
SKR2_POLLC_DATA_GAP_OCCURED |
A data gap occurred, due to the machine being operated too much time without network connection for example |
|
Meaning of the fields of SKR2_POLLC_MACHINE_REGTIME_STARTUP_PARAMETER:
1 /c=010 /v=1.E.3.149.6
eSTARTUP_MODE /c=MCSpec /v=McControlGeneration.McOS-Version
(Identical toMC status events, Event Type = 2, Event ID = 32001)
eSTARTUP_MODE |
Start mode |
---|---|
ecUndefined |
0 - Undefined |
ecWarmStart |
1 - Warm start |
ecDirectReStart |
2 - Restart |
ecReStart |
3 – Restart with configuration |
ecDirectColdStart |
4 - Cold start |
ecColdStart |
5 - Cold start with configuration |
ecReconfiguration |
6 - Reconfiguration (automatically done, e.g. with expiration of EVP, with mounting or removing Stixx or Ascon, with changing the coupling width of tandem machines) |
MCSpec |
Position of the digit |
---|---|
Digit 1 |
Tandem machine 0/1 |
Digit 2 |
Cancel Pattern Event possible (always 1) |
Digit 3 |
Yarn consumption info available (0/1) |
Further digits can occur in case of a function upgrade |
… |
McControlGeneration |
Control generation |
---|---|
1 |
OKC |
2 |
EKC |
3 |
CKC |
McOS Version |
Version of operating system |
---|---|
Example |
V.1.2.5 Corresponds to V_EKC_001.002.005_STOLL |