Maintenance
In this menu, you set up:
Vacuum
|
- Switch on or off the suction of the whole needle bed
- Number of courses with and without suction (1 course = 2 rows)
This menu point is only available if the suction is switched on.
Vacuum
|
Cleaning
|
Clean Selection Systems
- Carriage direction for cleaning course
- Quantity of courses till the needle selection systems get cleaned (1 course = 2 rows)
Clean Selection Systems
|
Lubricating
|
Manual Lubricating
- Set the quantity of system run-throughs until the next oil lubrication is required.
- Switch on or off the stop motion depending on whether the machine is to stop after the specified quantity of system run-throughs.
- Displays the quantity of the remaining system run-throughs until the next oiling of the needle bed.
Lubricating
|
Adjust central lubrication:
- Select the operating mode for the automatic lubrication.
- Set the quantity of system run-throughs until the next oil lubrication is required.
- Setting of the number of lubrication procedures after which the entire needle bed is to be lubricated.
- Displays the quantity of the remaining system run-throughs until the next oiling of the needle bed.
Lubricating
|
Lubricating
|
- Set the quantity of system run-throughs until the next oil lubrication is required.
- Switch on or off the stop motion depending on whether the machine is to stop after the specified quantity of system run-throughs.
- Displays the quantity of the remaining system run-throughs until the next oiling of the needle bed.
Lubricating
|