Light Curtain
Barriera luminosa |
Opens the Conferma barriera luminosa dialog box in order to check the correct orientation of the photoelectric sensors to each other.
|
Start the automatic check on EKC:
Both the elements at the left and right hand side of the machine must be aligned exactly to each other.
- All covers are closed.
- 446
- Revisiona macchina -> Servizio -> Barriera luminosa
- Conferma barriera luminosa appears.
- 447
- Tap the Avvia test key.
- The Barriera luminosa prompt appears:
Avviare controllo automatico? (durata circa 1-2 minuti) appears. - 448
- Confirm the prompt with Sì.
- The light curtain signalizes the alignment quality by the blue LEDs (1 to 5).
- If all 5 LEDs are glowing, the alignment is optimal.
- If 3 LEDs are glowing, the alignment is sufficient.
- If no LED is glowing the alignment is bad.
-> Re-align the light curtain!
When the check is completed successfully, the LEDs will go out.
No message appears at the touch screen.