Set racking basic correction VGK


The position of the rear needle bed relative to the front needle bed is set with the VGK value (factory setting).

If part of the racking device is replaced, e.g. the racking motor or the racking belt, the VGK value has to be set anew. During installation, make sure that the front and rear needle beds are opposite each other.
The VGK value always remains saved, even if the operating system is imported again.

Keys for setting VGK value

Key

Function

Call up the Service menu

Call up the Service Racking window

Confirm input

Call up Main menu

Adjusting VGK:

  1. Cast-off the stitches on both needle beds.
    1
    Call up Main menu.
    2
    Call up the Service menu.
    3
    Call up the Service Racking window.
  1. Service Racking window
  2. 4
    Enter and confirm the value 0 in the line VPK.
    5
    Tap the Racking adjusting run key. A message appears, answer this with Yes.
  3. The needle bed moves to the left and right. The racking will be synchronized.
  4. 6
    Tap the Reference run V>REF key. A message appears, answer this with Yes.
  5. The needle bed moves to the left and right. The racking is carrying out a reference run.
  6. 7
    Program an empty row with half racking and fix the knitting specification.
    8
    Push up several opposing needles at various positions of the needle bed (left, center, right) on both needle beds until the needle hooks touch each other.
    9
    Check whether the needle hooks of the front and rear needle bed are exactly in a line.
    10
    If this is not the case: Push back needles somewhat so that they do not touch each other anymore. In the VGK line, enter the value using the slider.

-1…-150

Correction to the left (1 step = 0.01 mm)

+1…+150

Correction to the right (1 step = 0.01 mm)

    11
    Confirm input.
  1. The needle bed moves lightly to the left or right.
  2. 12
    Check whether the needle hooks of the front and rear needle bed are exactly in a line.
    13
    If this is not the case, repeat steps 10 to 12 until the needle hooks of the front and rear needle beds are exactly positioned in one line.
    14
    The VGK value is automatically saved in the data specific to the machine (dongle data).
    15
    Adjust VPK value.
    (To be able to determine the VGK value you had to set the VPK value to 0 (in step 4). After having determined the VGK value you must set the VPK value again.)
  1. The setting process is complete.

如果需要,您也可以将VGK值保存在以下数据载体上:

可保存在U盘上

网络盘(按键“复制 Dongle”)

选针错误-一些针漏织

如果发生选针错误的情况,则“脉冲发生器-控制-选针系统”之间的同步出现问题。这是由于新旧VGK值之间差别太大造成的。

为重新建立同步,必须进行”选针偏移“测试。