中央润滑装置除气[Manually edited translation]
- 864
- 在针床外面停止机头。
- 865
- 稍微松开通风口螺丝 (7)。

- 866
- 将中央润滑装置旋入安装位置.
建议:因为将要给油, 请将清洁布放在中央润滑装置的下面。
- 867
- 激活 去除气泡 按钮。
机器维护保养 ->
润滑 ->
去除气泡
- 油泵会给油路供油。
- 868
- 如果有油从通风口螺丝的洞眼处渗出,则将 去除气泡 开关设置为关闭。
- 869
- 重新拧紧通风螺丝(9.5 Nm)。
- 870
- 对所有润滑装置进行除气操作。
- 871
- Stop the carriage on the needle bed.
- 872
- Activate the 去除气泡 button.
机器维护保养 ->
润滑 ->
去除气泡
- The pump supplies oil to the lubrication points.

- 873
- Feel the lubrication point for holding-down jacks next to the left needle brush with your finger.

- 874
- If oil leaks from the felt of the lubrication point for holding-down jacks, switch-off the 去除气泡 button.
- 875
- Check for oil leakage at the lubrication point for holding-down jacks of the opposite carriage.
- 876
- Push the carriage from the current location.
- 877
- Check the lubricated points on both of the needle beds and clean-up excess oil.
- Required for initial commissioning, after a long period of downtime or refilling
- Ensure that the lubricant container is free of bubbles.
- Consult the SKF Gear Pump Unit's instructions.
- 878
- Detach the oil line at the first metering device and lead it into the lubricant reservoir.

- 879
- Therefore, press the ring of the metering
device and tear out the line simultaneously.
- 880
- Activate the 去除气泡 button.
机器维护保养 ->
润滑 ->
去除气泡
- 881
- Only turn the 去除气泡 button off again when oil flows into the lubricant reservoir without bubbles.
- 882
- Plug the line into the metering device again.
- 883
- Repeat the ventilation process at the subsequent lubrication points.
- 884
- Run the pump until oil can be seen discharging at all lubrication points.
去除气泡