Exchanging and Adjusting Needle Brushes



The needle brushes must be adjusted when errors occur during stitch formation, e.g. drop stitches.

The needle brushes open the needle latches for inserting the thread.

The needle brushes are correctly adjusted when

Exchanging and Adjusting Needle Brushes:

Exchange needle brushes

  1. Loosen screws (7).
  2. Exchange needle brush.
  3. Retighten the screws (7).
  4. Exchange needle brushes on all systems.

Horizontal setting

  1. Loosen screws (1).
  2. Adjust needle brush.
  3. Retighten the screws (1).
  4. Adjust needle brushes on all systems.

Vertical setting

  1. Loosen screws (2).
  2. Adjust needle brush.
  3. Retighten the screws (2).
  4. Adjust needle brushes on all systems.

Notice

You can remove the cover (5) if needed.

  1. To do this, guide the hexagon socket through the through-hole (arrow) and loosen the screw (6).
  2. Remove cover (5).