Racking

Enter manually the correction values for the racking.

Основна Корекция на Чупката

The position of the rear needle bed relative to the front needle bed is set with the VGK value (factory setting).

If part of the racking device is replaced, e.g. the racking motor or the racking belt, the VGK value has to be set anew.

Корекция на Позицията на Чупката

Fine adjustment of the transfer racking.

The rear needle bed is aligned exactly relative to the front needle bed.

Adjusting racking position correction VPK

Основна Корекция на Задна Чупка

With this racking correction the rear additional needle bed is aligned exactly relative to the front needle bed.

Основна Корекция на Предна Чупка

With this racking correction the front additional needle bed is aligned exactly relative to the rear needle bed.

Enter manually the machine data

If the current values of the machine data have got lost, and there is no dongle data available, then the data can be entered manually.