Racking Positions and Racking Commands
Racking Positions
Designation | Symbol | Position of the needle bed |
---|---|---|
V0 | Normal Racking | |
V# | Half Racking | |
VU | Transfer Racking |
The maximum racking course of the rear needle bed covers 2 inch to left and 2 inch to the right starting from the home position 0.
Racking Functions
Command | Function |
---|---|
VCI n | n = 1 – 50 racking functions available.
|
General Commands for Racking
Commands | Designation / | Movement of the needle bed: |
---|---|---|
Racking Correction
| n = A – Z < = to the left > = to the right m = 1-10 |
|
m = 0 | Racking correction is turned off | |
m = ? | Machine stops at the given racking position in order to check the racking position and correct it if necessary. | |
Overracking
| n = 1 - 24 |
|
Racking speed
| n = 1-32 | Default setting: |
Notice:
- Racking of the rear needle bed is carried out in the carriage reversal.
- The racking commands are maintained for one carriage stroke.