Lubricating the CMS ADF

Additional lubrication points:

Lubrication interval

Lubricating work

Additional lubrication points with the CMS ADF

adjustable engaging width

Recommendation: Every 6 - 10 operating hours; select shorter interval if necessary

  • Oiling the needle bed

 

10 operating hours

  • Oiling the jack bed
  • Oiling the control of the holding-down jacks
  • Oiling the wires in the yarn carrier rails

100 operating hours

  • Greasing the impulse sensor rails
  • Greasing the coupling parts and the intermediate sliders

 

1 Month

 

  • Greasing the yarn carrier bows

2 months

 

  • Greasing the linear guiding of the carriage

6 months

  • Greasing the racking device
  • Greasing the needle bed supports