Adjusting Needle Brushes

The needle brushes must be adjusted when errors occur during stitch formation, e.g. drop stitches.

The needle brushes open the needle latches for inserting the thread. They are swivel-mounted so, that they are always inclined in the direction of travel of the carriage assembly.

The needle brushes are correctly adjusted when

Adjusting needle brushes:

    1
    Release hexagon nut (2).
    2
    Adjust needle brush at screw (1).
    3
    Retighten hexagon nut (2).
    4
    Adjust needle brushes on all systems.
    5
    Move the carriage at low speed and check the setting of the needle brushes.