Setting up the pattern

While the machine is knitting, the corresponding data of the knitting program is displayed for every carriage stroke and can be changed.

I. Setting up the loaded pattern:

  1. You are signed in as Senior Operator .
  2. An order with one knitting program was created.
  3. Quantity (run-throughs) is set.
  4. The order was started.
  5. The yarn carriers used in the knitting program are threaded-up.
    1
    Start the machine with the engaging rod.

1

Carriage stopped

2

reduced speed

3

normal speed

 

    2
    Tap on Set-up pattern in the bottom navigation bar.
  1. The window is displayed.

 

No.

Key

 

 

1

 

System specification

Display of the systems used with numbering

  • Light gray: System active
  • Dark gray: System inactive

 

Data for the rear needle bed

2

Opening of the Setup Editor for changing the stitch tension

 

  • Display of the current stitch tension (NP index) and the assigned value
  • Opens number field for direct change of the value
    : The value is directly transferred to Setup.

3

Opens the Test the weave-in device window

 

Graphic display of knitting symbols for the rear needle bed

 

4

Opening of the Setup Editor for changing of

  • YD /YDI
  • YC/YCI
  • Ua-b/NCC

 

  • Display of the active yarn carrier
  • Opens the Yarn carrier window with graphic display of the yarn carrier rails

 

Data for the front needle bed

 

Graphic display of knitting symbols for the front needle bed

5

Opens the Test the weave-in device window

6

Opening of the Setup Editor for changing the stitch tension

 

  • Display of the current stitch tension (NP index) and the assigned value
  • Opens number field for direct change of the value
    : The value is directly transferred to Setup.

7

 

Display of the currently knitting jacquard line number

8

Display of the currently knitting Sintral line number

9

  • Display of the take-down index with the current take-down value
  • Opening of the Setup Editors for changing data in the
    • WMF menu

10

  • Display of the auxiliary take-down index with the current speed of the auxiliary take-down.
  • Opening of the Setup Editors for changing data in the
    • W+F menu

11

   
0,70 m/s

  • Display of the carriage stroke direction with the current carriage speed
  • Opening of the Setup Editor for changing the carriage speed values (MSEC)

12

  • Display of the current cycle counter
  • Opening of the Setup Editor for changing the cycle counter

13

  • Display of the current racking correction index with the current racking position
  • Opening of the Setup Editor for changing the values of the racking correction index

 

    3
    Make the desired changes of the pattern parameters.
  1. The pattern should be set-up and prepared for the production.