Deaerate central lubrication

    1
    Stop carriage outside needle bed.
    2
    Loosen vent screw (7) somewhat.
  1. 3
    Swivel central lubrication into mounting position.
    Recommendation: Place a cleaning cloth under the central lubrication, as oil will be fed.
    4
    Activate the Deaeration button.
    Maintain Machine -> Lubricating -> Deaeration
  2. The pump feeds oil into the oil line.
  3. 5
    If oil comes out of the hole of the vent screw, switch off the Deaeration button.
    6
    Tighten vent screw again (9.5 Nm).
    7