Electrical data

Connection data of the knitting machine

Electrical data

Values

Supply voltage

230 / 400 V ±10 %
50 or 60 Hz

Phase number

1 (2)

Rated current

10 A

Protection of the mains to the knitting machine

16 A slow-blow

Mains supply, cross-section

CMS 202
CMS 303
CMS 330
CMS 330 W
CMS 502
CMS 503
CMS 520 C
CMS 530
CMS 530 B
CMS 530 BW
CMS 703

CMS 330
CMS 330 W
CMS 520 C
CMS 530
CMS 530 B
CMS 530 BW
CMS 703

CMS 330
CMS 330 W
CMS 520 C
CMS 530
CMS 530 B
CMS 530 BW
CMS 703
CMS 730 T
CMS 822
CMS 830
CMS 830 W
CMS 830 C
CMS 830 S
CMS 933

Connection value

CMS 202: 1.7 kW
CMS 303: 2.3 kW
CMS 330: 2.3 kW
CMS 330 W: 2.3 kW
CMS 502: 1.7 kW
CMS 503: 2.3 kW
CMS 520 C: 2.0 kW
CMS 530: 2.3 kW
CMS 530 W: 2.3 kW

CMS 530 BW: 2.3 kW
CMS 703: 2.3 kW
CMS 730 T: 2.3 kW
CMS 822: 2.6 kW
CMS 830: 2.3 kW
CMS 830 C: 2.3 kW
CMS 830 S: 2.7 kW
CMS 830 W: 2.3 kW
CMS 933: 3.0 kW

Before connecting the machine, check the mains voltage available on site.

It is generally not admissible to connect electrical or electronic components of other makes to the machine's internal wiring. A guarantee for a faultless function of the machine cannot be ensured in those cases.

If the knitting machine is operated with a generator, make sure that the voltage supplied by the generator meets the requirements of the EN 60204-1, Parag. 4.3.1.
In case of queries, please call the Stoll Helpline.