Ragbag
|
CMS 502 HP+ |
CMS 530 CMS 520 C+ |
CMS 530 MT CMS 730 T CMS 803 CMS 822 CMS 830 C CMS 830 S CMS 933 |
CMS ADF-3 |
CMS ADF 16 CMS ADF 32 |
---|---|---|---|---|---|
Supply voltage |
230 / 400 V ±10 % |
230 / 400 V ±10 % |
400 V ±10 % |
400 V ±10 % |
230 / 400 V ±10 % |
Phase number |
1 (2) |
1 (2) |
3 |
3 |
1 (2) |
Rated current |
10 A |
10 A |
7 A |
7 A |
10 A |
Protection of the mains to the knitting machine |
16 A slow-blow |
16 A slow-blow |
16 A slow-blow each phase |
16 A slow-blow each phase |
16 A slow-blow |
Mains supply |
|
|
|
|
|
single-phase |
X |
X |
- |
- |
X |
three-phase |
- |
X |
- |
- |
X |
three-phase |
- |
X |
X |
X |
X |
Connection value |
1.7 kW |
CMS 520 C+: 2,0 kW |
CMS 530 MT: 2,3 kW |
2,3 kW |
2,3 kW |
Electrical data |
Values | ||||||
---|---|---|---|---|---|---|---|
Supply voltage |
230 / 400 V ±10 % | ||||||
Phase number |
1 (2) | ||||||
Rated current |
10 A | ||||||
Mains supply |
single-phase |
three-phase |
three-phase | ||||
|
CMS 502 HP+ |
X |
- |
- | |||
CMS 530 CMS 520 C+ |
X |
X |
X | ||||
CMS 530 MT CMS 730 T CMS 803 CMS 822 CMS 830 C CMS 830 S CMS 933 |
- |
- |
X | ||||
CMS ADF-3 |
- |
- |
X | ||||
CMS ADF 16 CMS ADF 32 |
X |
X |
X | ||||
Protection of the mains to the knitting machine |
16 A slow-blow |
16 A slow-blow each phase |
16 A slow-blow each phase | ||||
Connection value |
CMS 502 HP+ |
1.7 kW |
CMS 822 |
2.6 kW |
Electrical data |
Values | ||||||
---|---|---|---|---|---|---|---|
Supply voltage |
230 / 400 V ±10 % | ||||||
Phase number |
1 (2) | ||||||
Rated current |
10 A | ||||||
Mains supply |
single-phase |
three-phase |
three-phase | ||||
|
CMS 502 HP+ |
X |
- |
- | |||
CMS 530 CMS 520 C+ |
X |
X |
X | ||||
CMS 530 MT CMS 730 T CMS 803 CMS 822 CMS 830 C CMS 830 S CMS 933 |
- |
- |
X | ||||
CMS ADF-3 |
- |
- |
X | ||||
CMS ADF 16 CMS ADF 32 |
X |
X |
X | ||||
Protection of the mains to the knitting machine |
16 A slow-blow |
16 A slow-blow each phase |
16 A slow-blow each phase | ||||
Connection value |
CMS 502 HP+ |
1.7 kW |
CMS 822 |
2.6 kW |
Before connecting the machine, check the mains voltage available on site.
It is generally not admissible to connect electrical or electronic components of other makes to the machine's internal wiring. A guarantee for a faultless function of the machine cannot be ensured in those cases.
If the knitting machine is operated with a generator, make sure that the voltage supplied by the generator meets the requirements of the EN 60204-1, Parag. 4.3.1.
In case of queries, please call the Stoll Helpline.