Oil needle bed

Recommendation: Every 6 - 10 operating hours; select shorter interval if necessary

Stolltex T46

E3│E3,5│E4│E5│E7│E8│E2,5.2│E3,5.2│E5.2│
E10│E12│E14│E6.2│E7.2

Stolltex T32

E16│E18│E20│E8.2│E9.2│E10.2

    1
    Apply oil with a brush or spray bottle.
    2
    Brushes are attached at the side of the needle bed. Put some oil in the upper brush so that the cams near the coupling parts are oiled.
    3
    Oil the thread clamping and cutting device.
    4
    Restarting lubricating interval.

Restarting lubricating interval

Set lubrication interval for needle bed