Set lubrication interval for needle bed


Between 1 and 65,535 courses can be set as a lubricating interval for the needle bed. An average value for a two-system machine is 30,000 courses (15,000 courses per knitting system). However, this value depends highly on: Machine speed, temperature and number of knitting systems. We recommend: Selecting a shorter lubricating interval instead of a longer one. After the lubricating interval expires, a message appears stating that the needle bed must be oiled.

Set lubricating interval:

    1
    Open the ေခ်ာဆီထိုးျခင္း menu.
    စက္ကို စီစဥ္သတ္မွတ္ရန္ -> ထိန္းသိမ္းမႈ -> ေခ်ာဆီထိုးျခင္း
    2
    Tap the button (1).
  1. 3
    Enter the value after how many system run-throughs the needle bed should be oiled manually.
    4
    Confirm the entry with အိုေက.
  2. 5
    If the machine is to stop after reaching the specified number of system run-throughs, , the button (2) must be switched on (active).
  3. The machine stops and the error message Oil needle bed is displayed.
  4. 6
    If the button (2) is switched off (inactive), the machine does not stop.
    The message Oil needle bed is shown on the display.