Racking Positions and Racking Commands
Racking Positions
| 
                       Designation  | Symbol  | Position of the needle bed  | 
|---|---|---|
V0  | Normal Racking  | 
  | 
V#  | Half Racking  | 
  | 
VU  | Transfer Racking  | 
  | 
The maximum racking course of the rear needle bed covers 2 inch to left and 2 inch to the right starting from the home position 0.
Racking Functions
| 
                       Command  | Function  | 
|---|---|
VCI n  | n = 1 – 50 racking functions available. 
  | 
General Commands for Racking
| 
                       Commands  | Designation /  | Movement of the needle bed:  | 
|---|---|---|
Racking Correction 
  | n = A – Z < = to the left > = to the right m = 1-10  | 
 
  | 
m = 0  | Racking correction is turned off  | |
m = ?  | Machine stops at the given racking position in order to check the racking position and correct it if necessary.  | |
Overracking 
  | n = 1 - 24  | 
 
  | 
Racking speed 
  | n = 1-32  | Default setting:  | 
              
 Notice:
- Racking of the rear needle bed is carried out in the carriage reversal.
 - The racking commands are maintained for one carriage stroke.
(stroke-related data) - Additional racking commands are used for machines with additional beds.
 