Clean the Suction and Control Unit (component type 00)

I. Clean the lint container and the suction turbine:

    1
    Slide on cover over needle bed.
    2
    Push the lock of the lint container (1) toward the rear and pull away the container downward.
    3
    Empty the lint container.
  1. 4
    Clean the filter (2) in the lint container and the filter (3) at the vacuum device.
    5
    Reinstate the lint container.
    6
    Remove left rear panel segment.
  2. 7
    Clean motor cover.

II. Clean the suction tube:

    1
    Remove the suction tube (4) from the carriage and blow it out with compressed air.

II. Cleaning at the left and right control unit:

    1
    Switch off machine.
    Set the main switch to 0 and wait until the touch screen is switched off.
    2
    Remove the covers of the left and right control unit.
    3
    Control unit on the left:
    Vacuum off both filter mats, remove them and blow them out.
    Reassemble them.
    4
    Control unit on the right:
    Vacuum off and blow out the fan and radiator.
    5
    Fix the covers of both control units.