Light Curtain

Işık perdesi

Opens the Işık perdesini test et dialog box in order to check the correct orientation of the photoelectric sensors to each other.

Start the automatic check on EKC:

Both the elements at the left and right hand side of the machine must be aligned exactly to each other.

  1. All covers are closed.
    1
    Makineyi bakıma al -> Servis -> Işık perdesi
  1. Işık perdesini test et appears.
  2. 2
    Tap the Testi başlat key.
  3. The Işık perdesi prompt appears:
    Otomatik test başlatılsın mı? (Süre yakl. 1-2 dakika) appears.
  4. 3
    Confirm the prompt with Evet.
  1. The light curtain signalizes the alignment quality by the blue LEDs (1 to 5).
  • If all 5 LEDs are glowing, the alignment is optimal.
  • If 3 LEDs are glowing, the alignment is sufficient.
  • If no LED is glowing the alignment is bad.
    -> Re-align the light curtain!


When the check is completed successfully, the LEDs will go out.
No message appears at the touch screen.