Oil and grease needle bed

Recommendation: Every 6 - 10 operating hours; select shorter interval if necessary

Stolltex T46

E1,5.2│E2.2│E3│E3,5│E4│E5│E7│E8│E2,5.2│E3,5.2│E5.2│
E10│E12│E14│E6.2│E7.2

Stoll Grease 0475

The pictographs Oil needle bed and Lubricate needle beds are displayed together.
Start oiling the needle bed elements and then grease the butts of the coupling parts and intermediate sliders.

    1
    Apply oil with a brush or spray bottle.
  1. 2
    Brushes are attached at the side of the needle bed. Put some oil in the upper brush so that the cams near the coupling parts are oiled.
    3
    Oil the thread clamping and cutting device.
    4
    Use a brush to apply grease on the butts of the coupling parts and intermediate sliders.
  2. 5
    Restarting lubricating interval.

Restarting lubricating interval

Set lubrication interval for needle bed