Lubrication

With this menu you confirm the corresponding lubrication process:

Racking Spindle

Days Prior to Next Greasing

Display of the time (by days) until the next lubrication process.

Confirm Greasing

Click this button only if the greasing process actually was performed.

In case of insufficient grease, there is the risk of damaging the racking spindle. An irreversible damage of the racking spindle is possible!

Greasing racking device

Racking Spindle

Days Prior to Next Greasing

Display of the time (by days) until the next lubrication process.

Confirm Greasing

Click this button only if the greasing process actually was performed.

In case of insufficient grease, there is the risk of damaging the racking spindle. An irreversible damage of the racking spindle is possible!

Greasing racking device

Needle Bed

System Run-throughs Prior to Next Oiling

Displays the quantity of the system run-throughs until the next oiling of the needle bed.

Confirm Oiling

Tap on this button only if the oiling process actually was performed.

Oil needle bed

Oiling Intervals Prior to Next Greasing

After every tenth Oil needle bed note appears a Lubricate needle beds pictograph.

Confirm Greasing

Click this button only if the greasing process actually was performed.

Greasing butts of the coupling parts and intermediate sliders

Needle Bed

System Run-throughs Until Lubricating Process

Displays the quantity of the system run-throughs until the next oiling of the needle bed.

Confirm Oiling of Needle Bed

Tap on this button only if the oiling process actually was performed.

Oil needle bed

Confirm Greasing of Needle Bed

Click this button only if the greasing process actually was performed.

Greasing butts of the coupling parts and intermediate sliders

Needle Bed

System Run-throughs Until Lubricating Process

Displays the quantity of the system run-throughs until the next oiling of the needle bed.

Confirm Oiling

Tap on this button only if the oiling process actually was performed.

Oil and grease needle bed

Confirm Greasing

Click this button only if the greasing process actually was performed.

Oil and grease needle bed

Linear Guiding of the Carriage

Operating Time Prior to Next Greasing

Display of the time (by hours) until the next lubrication process.

If the maximum value for the run time or the distance is reached, the machine stops. The 20657 Grease the linear guiding of the carriage message appears on the display.

Greasing the Linear Guiding

Distance Prior to Next Greasing

Display of the distance (in kilometers) until the next last lubrication process.

If the maximum value for the run time or the distance is reached, the machine stops. The 20657 Grease the linear guiding of the carriage message appears on the display.

Greasing the Linear Guiding

Operating Hours

Display of the previous operating time of the carriage (operating hours counter)

Kilometers

Display of the traveled distance of the carriage (kilometer counter)

Confirm Greasing

Click this button only if the greasing process actually was performed. In case of insufficient grease, there is the risk of damaging the linear guiding.

An irreversible damage of the linear guiding is possible!

Needle Bed

System Run-throughs Until Lubricating Process

Displays the quantity of the system run-throughs until the next oiling of the needle bed.

For central lubrication Type1
The selection jacks have to be oiled manually.

Central Lubrication - Differences of Type 1, Type 2 and Type 3

Trigger a Lubrication Process

The central lubrication lubricates the whole needle bed once.

Deaeration

Tap here to deaerate the oil line of central lubrication.

Deaerate central lubrication