Remove the carriage part to replace cams
I. Remove the carriage part from the needle bed
Central lubrication
If a central lubrication is present, swivel it into mounting position.
- 1
- Move the carriage assembly outward up to the support surface.
- 2
- Deactivate the power supply .
- 3
- Remove the carriage assembly panelling (1).
- 4
- If the rear carriage part is removed, the needle detector is to be removed as well.
- 5
- Mark the position of the needle detector so that it can be reassembled in the same position.
- 6
- Remove the suction tube on the carriage assembly.
- 7
- Remove the shoulder screws (2) and screws (4) on the left and right-hand sides.
- 8
- Swivel left and right swiveling plates (5) inward.
- 9
- Loosen the screws on the plugs (3) and pull out the plugs.
- 10
- Press the Release drive brake [>!] button below Intervene Manually II
- 11
- Push away the carriage assembly.
If the carriage assembly is blocked:
The drive brake has automatically closed.
- 12
- Lift the carriage part off the support surface.
- or -
Open the side safety door hood and lift out the carriage part to the side. - 13
- To replace the cams, turn the cam plate upward.