Connect mains supply to the main switch

The knitting machine must be connected in the right-hand rotating field.

The mains supply is either led from the floor (1) to the main switch or from the ceiling through the right support (2) of the yarn feeding and control device to the main switch.

Mains supply
Mains supply
    1
    Determine the direction of rotation of the mains supply.

DANGER

danger

Life-threatening high voltage!

Electrical shock may cause death or serious injuries.

  1. Deenergize on-site mains supply.
    2
    Open the mains switch housing.

Potential equalization missing!
Serious errors or faults can be caused in the machine and the electronic circuit if the terminal PE is not connected.
-> Terminal PE to be connected always

    3
    Connect the mains supply to the terminals L1, L2, L3 and N of the terminal strip and to the yellow-green protective conductor (PE).
    4
    Close the main switch housing.

The right connection of the mains supply is controlled (right-hand rotating field: Terminals L1, L2, L3 (R, S, T)). If the 04272 Power Supply Phase Sequence Wrong message appears on the touch screen, then the connection is wrong.

Correction of the error 04272 Power Supply Phase Sequence Wrong:

DANGER

danger

Life-threatening high voltage!

Electrical shock may cause death or serious injuries.

  1. Interrupt the mains supply to the machine.
    It is not sufficient to simply switch off the machine at the main switch!
    1
    Swap the two phases of the mains supply.