Connect mains supply to the main switch

DANGER

danger

Life-threatening high voltage!

Electrical shock may cause death or serious injuries.

  1. The knitting machine must be connected by an electrician.
  2. Country-specific laws and regulations are to be followed.

The knitting machine must be connected in the right-hand rotating field.

The mains supply is either led from the floor (1) to the main switch or from the ceiling through the right support (2) of the yarn guide device to the main switch.

Mains supply
Mains supply
    1
    Determine the direction of rotation of the mains supply.

DANGER

danger

Life-threatening high voltage!

Electrical shock may cause death or serious injuries.

  1. Deenergize on-site mains supply.
    2
    Open the mains switch housing.

Potential equalization missing!
Serious failures or faults can be caused in the machine and the electronic circuit if the terminal (PE) is not connected.
-> Always connect terminal .

    3
    Connect the mains supply to the terminals L1, L2, L3 and N (if present) and to the terminal for the protective conductor "PE".
    4
    Close the main switch housing.

The right connection of the mains supply is controlled (right-hand rotating field: Terminals L1, L2, L3 (R, S, T)). If the signal 04272 Power Supply Phase Sequence Wrong appears on the touch screen the connection is wrong.

Correction of the error 04272 Power Supply Phase Sequence Wrong:

DANGER

danger

Life-threatening high voltage!

Electrical shock may cause death or serious injuries.

  1. Interrupt the mains supply to the machine.
    It is not sufficient to simply switch off the machine at the main switch!
    1
    Swap the two phases of the mains supply.