Connect mains supply

DANGER

danger

Life-threatening high voltage!

Electrical shock may cause death or serious injuries.

  1. The knitting machine must be connected by an electrician.
  2. Country-specific laws and regulations are to be followed.

Lead the mains supply cable to the right control cabinet:

Mains supply
Mains supply

The machine will be delivered ready to plug. The mains supply cable is fitted with a CEE male plug, the matching CEE female plug (3) is attached.

How to connect the mains supply:

    1
    Determine the direction of rotation of the mains supply.

DANGER

danger

Life-threatening high voltage!

Electrical shock may cause death or serious injuries.

  1. Deenergize on-site mains supply.
    2
    Open the cover at the right control cabinet.
    3
    Unplug the CEE plug (3).
    4
    Connect the CEE female plug to the mains supply. The knitting machine must be connected in the right-hand rotating field.
    Connect the mains supply to the terminals L1, L2, L3 and N (if present) and to the terminal for the protective conductor "PE".

Potential equalization missing!
Serious failures or faults can be caused in the machine and the electronic circuit if the terminal (PE) is not connected.
-> Always connect terminal .

    5
    Plug in the CEE plug again.
    6
    Close the cover at the right control cabinet again.

The right connection of the mains supply is controlled (right-hand rotating field: Terminals L1, L2, L3 (R, S, T)). If the 04272 Power Supply Phase Sequence Wrong message appears on the touch screen the connection is wrong.

Correction of the error 04272 Power Supply Phase Sequence Wrong:

DANGER

danger

Life-threatening high voltage!

Electrical shock may cause death or serious injuries.

  1. Deenergize on-site mains supply.
    1
    Swap the two phases of the mains supply.