Connect mains supply
DANGER
Life-threatening high voltage!
Electrical shock may cause death or serious injuries.
- The knitting machine must be connected by an electrician.
- Country-specific laws and regulations are to be followed.
Lead the mains supply cable to the right control cabinet:
- via the floor (1)
- coming from the ceiling (2) through the right support of the yarn guide device
How to connect the mains supply:
DANGER
Life-threatening high voltage!
Electrical shock may cause death or serious injuries.
- Deenergize on-site mains supply.
- The main switch is switched off ( )
- The mains supply to the machine is unplugged (currentless)
- 1
- Open the cover at the right control cabinet.
- 2
- Press the release button (1) and unplug the plug (2).
- 3
- Open the plug (2) and connect to the mains supply (3a) or·(3b).
|
Mains supply (3a) |
Mains supply (3b) |
Example for mains symmetry | ||
Connection variant |
| ||||
Plug (2) |
|
|
|
| |
L1 |
L1 |
L1 |
L2 |
L3 | |
L2 * |
- |
L2 ** |
L3 ** |
L1 ** | |
L3 * |
- |
L3 ** |
L1 ** |
L2 ** | |
N |
N |
N |
N |
N | |
PE |
PE |
PE |
PE |
PE | |
* L2 and L3 are not used internally in the machine. Therefore, the phases of the operational mains supply must be distributed evenly on L1, L2 and L3. | |||||
** if available |
- 4
- Make sure that the operational mains supply is loaded evenly (mains symmetry). You will find the connection variants (, , ) in the above table.
WARNING
Potential equalization missing!
Serious failures or faults can be caused in the machine and the electronic circuit if the terminal (PE) is not connected.
- Always connect terminal .
- 5
- The terminal for the protective conductor "PE" must be connected.
- 6
- Close the plug (2) and connect it to the main switch.
- 7
- Open the main switch.
For this, loosen the 4 screws and remove the cover of the main switch. - 8
- Connect the plug (4) on the left side.
- 9
- Close the main switch.