Connect mains supply

DANGER

danger

Life-threatening high voltage!

Electrical shock may cause death or serious injuries.

  1. The knitting machine must be connected by an electrician.
  2. Country-specific laws and regulations are to be followed.

Lead the mains supply cable to the left control cabinet:

How to connect the mains supply:

DANGER

danger

Life-threatening high voltage!

Electrical shock may cause death or serious injuries.

  1. Deenergize on-site mains supply.
  1. The main switch is switched off (0)
  2. The mains supply to the machine is unplugged (currentless)
    1
    Open the cover at the left control cabinet.
    2
    Press the release button (1) and unplug the plug (2).

 

    3
    Open the plug (2) and connect to the mains supply (3).

 

 

Mains supply (3)

Example for mains symmetry

Connection variant

Plug (2)

L1

L1

L2

L3

L2

L2

L3

L1

L3 *

L3 **

L1 **

L2 **

N

N **

N **

N **

PE

PE

PE

PE

* L3 is not used internally in the machine. Therefore, the phases in the plug (2) must be distributed evenly on L1 and L2.

** if available

    4
    Make sure that the operational mains supply is loaded evenly (mains symmetry). You will find the connection variants (, , ) in the above table.

WARNING

warning

Potential equalization missing!

Serious failures or faults can be caused in the machine and the electronic circuit if the terminal (PE) is not connected.

  1. Always connect terminal .
    5
    The terminal for the protective conductor "PE" must be connected.
    6
    Close the plug (2) and connect it to the main switch.
    7
    Open the main switch.
    For this, loosen the 4 screws and remove the cover of the main switch.
  1. 8
    Remove the plug (4) from the left side and connect it on the right side.
  2. 9
    Close the main switch.
    10
    Close the cover at the right control cabinet again.