Connect mains supply
DANGER
![danger](../safety/general_general.gif)
Life-threatening high voltage!
Electrical shock may cause death or serious injuries.
- The knitting machine must be connected by an electrician.
- Country-specific laws and regulations are to be followed.
Lead the mains supply cable to the left control cabinet:
![](../Images/png/7883444107__Web.png)
- via the floor (1)
- coming from the ceiling (2) through the left support of the yarn guide device
How to connect the mains supply:
DANGER
![danger](../safety/general_general.gif)
Life-threatening high voltage!
Electrical shock may cause death or serious injuries.
- Deenergize on-site mains supply.
- The main switch is switched off ( )
- The mains supply to the machine is unplugged (currentless)
- 1
- Open the cover at the left control cabinet.
- 2
- Press the release button (1) and unplug the plug (2).
![](../Images/png/7883425675__Web.png)
- 3
- Open the plug (2) and connect to the mains supply (3).
![](../Images/png/12954571659__Web.png)
|
Mains supply (3) |
Example for mains symmetry | ||
Connection variant |
| |||
Plug (2) |
|
|
| |
L1 |
L1 |
L2 |
L3 | |
L2 |
- |
- |
- | |
L3 |
- |
- |
- | |
N |
Lx |
Lx |
Lx | |
PE |
PE |
PE |
PE |
- 4
- Make sure that the operational mains supply is loaded evenly (mains symmetry). You will find the connection variants (
,
,
) in the above table.
WARNING
![warning](../safety/general_general.gif)
Potential equalization missing!
Serious failures or faults can be caused in the machine and the electronic circuit if the terminal (PE) is not connected.
- Always connect terminal
.
- 5
- The terminal
for the protective conductor "PE" must be connected.
- 6
- Close the plug (2) and connect it to the main switch.
- 7
- Open the main switch.
For this, loosen the 4 screws and remove the cover of the main switch. - 8
- Connect the plug (4) on the left side.
- 9
- Close the main switch.
- 10
- Close the cover at the right control cabinet again.