Connect mains supply
DANGER
Life-threatening high voltage!
Electrical shock may cause death or serious injuries.
- The knitting machine must be connected by an electrician.
- Country-specific laws and regulations are to be followed.
Lead the mains supply cable to the left control cabinet:
- via the floor (1)
- coming from the ceiling (2) through the left support of the yarn guide device
How to connect the mains supply:
DANGER
Life-threatening high voltage!
Electrical shock may cause death or serious injuries.
- Deenergize on-site mains supply.
- The main switch is switched off ( )
- The mains supply to the machine is unplugged (currentless)
- 1
- Open the cover at the left control cabinet.
- 2
- Connect the cable (3) to the mains supply.
Mains supply | Example for mains symmetry | ||
Connection variant | |||
L1 | L2 | L3 | |
L2 | L3 | L1 | |
L3 | L1 | L2 | |
N | N | N | |
PE | PE | PE |
- 3
- Make sure that the operational mains supply is loaded evenly (mains symmetry). You will find the connection variants (, , ) in the above table.
WARNING
Potential equalization missing!
Serious failures or faults can be caused in the machine and the electronic circuit if the terminal (PE) is not connected.
- Always connect terminal .
- 4
- The terminal for the protective conductor "PE" must be connected.
Check the cable
- 1
- Depending on the mains voltage different cables (1) are used.
Mains voltage | Cable (ID) |
---|---|
400 V / 230 V | 273 263 |
230 V /120 V, "Phase-Phase" | 274 033 |
Check the position of the plug
For doing this, proceed as follows:
- 1
- Open the main switch.
For this, loosen the 4 screws and remove the cover of the main switch. - 2
- The plug (4) must be inserted on the left side (230 V).
- 3
- Close the main switch.
Check the wiring in the transformer
For doing this, proceed as follows:
- 1
- Open the cover on the transformer.
- 2
- The cables must be inserted into the terminals "220 V".
- 3
- Close the cover on the transformer.
- 4
- Close the cover at the left control cabinet again.