Connect mains supply

DANGER

danger

Life-threatening high voltage!

Electrical shock may cause death or serious injuries.

  1. The knitting machine must be connected by an electrician.
  2. Country-specific laws and regulations are to be followed.

Lead the mains supply cable to the left control cabinet:

How to connect the mains supply:

DANGER

danger

Life-threatening high voltage!

Electrical shock may cause death or serious injuries.

  1. Deenergize on-site mains supply.
  1. The main switch is switched off (0)
  2. The mains supply to the machine is unplugged (currentless)
    1
    Open the cover at the left control cabinet.
    2
    Connect the cable (3) to the mains supply.

Mains supply

Example for mains symmetry

Connection variant

L1

L2

L3

L2

L3

L1

L3

L1

L2

N

N

N

PE

PE

PE

    3
    Make sure that the operational mains supply is loaded evenly (mains symmetry). You will find the connection variants (, , ) in the above table.

WARNING

warning

Potential equalization missing!

Serious failures or faults can be caused in the machine and the electronic circuit if the terminal (PE) is not connected.

  1. Always connect terminal .
    4
    The terminal for the protective conductor "PE" must be connected.

Check the cable

    1
    Depending on the mains voltage different cables (1) are used.

Mains voltage

Cable (ID)

400 V / 230 V

273 263

230 V /120 V, "Phase-Phase"

274 033

Check the position of the plug

For doing this, proceed as follows:

    1
    Open the main switch.
    For this, loosen the 4 screws and remove the cover of the main switch.
  1. 2
    The plug (4) must be inserted on the left side (230 V).
  2. 3
    Close the main switch.

Check the wiring in the transformer

For doing this, proceed as follows:

    1
    Open the cover on the transformer.
  1. 2
    The cables must be inserted into the terminals "220 V".
    3
    Close the cover on the transformer.
    4
    Close the cover at the left control cabinet again.