Clean the knitting systems

Stolltex T46

E1,5.2│E2.2│E3│E3,5│E4│E5│E7│E8│E2,5.2│
E3,5.2│E5.2│E10│E12│E14│E6.2│E7.2

Stolltex T32

E16│E18│E20│E8.2│E9.2│E10.2

    1
    Stop the knitting machine.
    2
    Move the carriage assembly into the left reversing position.
    3
    Set the main switch to 0 and wait until the touch screen is switched off.
    4
    Remove the carriage part.

UWAGA

notice

Damage to the knitting systems!

Dirt will be blown into the guides of the movable parts and the knitting systems will be damaged if they are blown out with compressed air.

  1. Always vacuum off the knitting systems, never blow them out.
    5
    Vacuum off the knitting systems and selection systems.

UWAGA

notice

Damage to the selection systems and impulse givers!

The selection systems and impulse givers will be damaged if they are cleaned with acetone or trichlorethylene (Tri).

  1. Clean the selector systems and impulse sensors with a clean cloth.
    6
    Clean the selector systems and impulse sensors with a clean cloth.
    7
    Check the cams for wear and damage.
    8
    Apply oil onto the cams with a brush.
    9
    Set the carriage part on the needle bed again.
    10
    Repeat step 4 to 9 for all carriage parts.
    11
    Set the main switch to 1.
  1. The carriage position is re-referenced.