Remove the carriage part to replace the cams
I. Remove the carriage part from the needle bed
- 1
- Move the carriage assembly outward up to the support surface.
- 2
- Deactivate the power supply .
- 3
- Open the covers.
- 4
- Move the yarn carrier from the clamping and cutting area into the needle bed.
Reason: When lifting the carriage part, the yarn carriers can be damaged. - 5
- Remove the carriage assembly panelling (1).
- 6
- Take the suction tubes (2) out of the carriage part.
- 7
- Loosen the screws on the plugs (3) and pull out the plugs.
- 8
- Remove the shoulder screws (4) and screws (5) on the left and right-hand sides.
- 9
- Swivel left and right swiveling plates (6) inward.
- 10
- Press the Release drive brake [>!] button below Intervenție manuală II
- 11
- Push away the carriage support to the machine center.
If the carriage support blocks:
The drive brake has automatically closed.
- 12
- Remove carriage part from machine.
- 13
- To replace the cams, turn the cam plate upward.