Remove the carriage part to replace the cams

I. Remove the carriage part from the needle bed

    1
    Move the carriage assembly outward up to the support surface.
    2
    Deactivate the power supply 40 Volt .
    3
    Open the covers.
    4
    Move the yarn carrier from the clamping and cutting area into the needle bed.
    Reason: When lifting the carriage part, the yarn carriers can be damaged.
  1. 5
    Remove the carriage assembly panelling (1).
  2. 6
    Take the suction tubes (2) out of the carriage part.
  3. 7
    Loosen the screws on the plugs (3) and pull out the plugs.
    8
    Remove the shoulder screws (4) and screws (5) on the left and right-hand sides.
  4. 9
    Swivel left and right swiveling plates (6) inward.
    10
    Press the Release drive brake [>!] button below Manuel müdahale II
    11
    Push away the carriage support to the machine center.

If the carriage support blocks:

The drive brake has automatically closed.

    12
    Remove carriage part from machine.
    13
    To replace the cams, turn the cam plate upward.