Overview of the YLC modes 1 – 8 (up to OKC operating system V. 2.7)
| Designation | Explanation |
---|---|---|
YLC1 | Measuring + regulating, depending on <-> |
|
YLC2 | Adjusting stitch cams |
|
YLC3 | Measuring in test fabric for mode 1, 7 or 8 | Generate test fabric piece before starting the production. |
YLC4 | Determine measuring + correction values for modes 1, 7 or 8. |
|
YLC5 | Measuring in the original fabric for mode 6 |
|
YLC6 | Regulating with values from mode 5 | The YLC5 data is used as target value for all further fabrics. |
YLC7 | Measuring + regulating, independent of <-> |
|
YLC8 | Measuring + regulating, depending on <-> and S1-Sn |
|
YLC0 | Switch off (neither measure nor control) |
YLC0 indicates that a YLC device is logged-on on the machine. |
Application areas of the modes
Pattern | If required: | Generate original fabric (Master Piece) | Production |
---|---|---|---|
| YLC4 Determine correction values before the production |
| YLC1 A separate correction value is determined for each carriage direction. |
YLC3 Determining correction values with test fabric piece | YLC8 A separate correction value is determined for each carriage direction and knitting system. | ||
YLC7 A correction value is determined independent from the carriage direction. | |||
|
| YLC5 | YLC6 The YLC5 data is used as target value for all further fabrics. |