Alarms of Machine Events

In this area you configure the threshold values for machine events in the alarm system.

    1
    In the Message area section of the Configuration window in the Stop motion number... field, enter one or more combinations from the machine status numbers and stop motion error numbers of the machine which the PPS is to interpret as a trigger regarding a stop motion.
    Format: Machine status number[:[-]Error number,[-]Error number],...]; Machine status number [:[-]Error number,[-]Error number,...];… .
    If only the machine status number is indicated, then all the error numbers will be considered for a message or alarm.

A machine state can also be considered only in case of simultaneous occurrence of message numbers. You enter the message numbers behind a machine state after a colon separated by a comma.

A machine always is in a state represented by the machine state and and to which is assigned a number.
MC status events and Machine state: Colors and symbols
Messages that are output by the machine have a number as well.
Help to Error Messages.
These messages appear during a machine state.

You can trigger a PPS message or PPS alarm output if the machine enters into a state or if a specific combination of state and message occurs.

Combinations that already occurred can be found in the Event list report for EVENT_TYP=2 in the EVENT_PARAM field.
If no error numbers are indicated, then the machine status is always considered.
If a minus appears in front of the error number, it will be excluded and will not be considered for a message or alarm.

Example:

    1
    Select the Save button.
  1. In the Configuring user-specific notifications mask, you can book the events that are described below via the Machine events event.
  1. The alarm configuration of machine events will be implemented immediately.